topeeng.gif (8383 bytes)

[ Scientific Activity - Actividad Científica ] [ Brief Communications - Temas Libres ]

Cardiac resonance: Our Experience
Resonancia Cardíaca. Nuestra experiencia.

Alessio Eva; Fortuny M.Eugenia; Cedola Jorge; Ciucci Daniel; Alvarez Carlos; Corsiglia Daniel.

CIMED-FUNDAMI
La Plata. - Argentina

Abstract (Español)
Abstract (English)
Poster

Abstract
Objetivo: Determinar la utilidad de la RM como método alternativo en el diagnóstico de la patología cardiovascular en base a ser un método no invasivo, de alta definición anatómica y con posibilidades de realizar estudios multiplanares y funcionales.
Material y método: se estudiaron 11 pacientes, 7 hombres y 4 mujeres, entre 17 y 71 años de edad, con un equipo G.E. 0,5 Tesla Sigma Advantage, bobina de cuerpo y secuencias SPIN ECO T1 y T2 multiplanares, secuencias ecogradientes y cine cardíaco.
Resultados: Luego de analizados los pacientes encontramos:
1 quiste hidatídico de septun y pericardio: Imagem hetereogénea con centro probablemente quístico en septum interventricular, con engrosamiento y derrame pericárdico.
1 Pericarditis constrictiva: Engrosamiento pericárdico sectorial que alcanza 1,3 cm de espesor.
1 C.I.V. + ductus: Comunicación interventricular alta con ductus aorto pulmonar de 2,9 cm.
1 C.I.V. + hipoplasia del T.S.V.D.: Disminución de los diámetros del tracto de salida del V.D.
1 Coartación de aorta: Disminición del calibre de la aorta en región posductal.
1 Coartación de aorta operada: Disminución del calibre aórtico en región posductal (reestenosis).
1 Síndrome de Marfan: Dilatación aneurismótico de raíz de aorta de 51mm. Aneurisma del seno de Valsalva no coronario.
2 Mixoma auricular izquierdo: Masa sólida, de bordes bien delimitados, en el interior de la aurícula izquierda.
2 Disección aórtica: Dilatación aneurismática de aorta con flap de disección tipo III, observándose verdadera y falsa luz. En todos los casos se evidenció una importante resolución anatómica, con iconografía significativa.
Conclusión: La R.M.I. es un método no invasivo de alta resolución anatómica, con amplias posibilidades en la resolución multiplanar, que admiten en el caso puntual de la patología cardíaca el acceso a áreas del corazón y mediastino que no son fácilmente visualizados con otros métodos.

Top

Abstract
Objectives: Determining MR usefulness as alternative method in the diagnosis of cardiovascular pathology based on being a non-invasive method, of high anatomic definition, with chances of performing functional and multiplanar studies.
Material and Methods: 11 patients were admitted to the study, 7 were men and 4 women, their ages ranging from 17 to 71, with a G.E. 0,5 Tesla Sigma Advantage equipment, body coil and multiplanar SPIN ECO T1 and T2 sequences, ecogradient sequences and cardiac cinecoronarygraphy.
Results: after having analyzed the patients we found:
1 Hydatid cyst of septum and pericardium: Heterogeneous image with probably cystic center in interventricular septum, with pericardial effusion and thickening.
1 Astringent Pericarditis: Pericardial sectorial thickening reaching 1,3 cm thick.
1 I.V.C.+ ductus: High interventricular communication with aorto pulmonary ductus of 2,9 cm
1 I.V.C. + hypoplasia of E.T.R.V.: Decrease of the diameters of the exit tract of R.V.
1 Coartation of aorta: Decrease of the aorta caliber in postductal region.
1 Operated Coartation of aorta: Decrease of the aortic caliber in postductal region (restenosis).
1 Marfan Syndrome: Aneurysmatic dilation of the aorta root of 51 mm. Aneurysm of non-coronary Valsalva sinus.
2 Left atrial myxoma: Solid mass, of well-defined edges, inside the left atrium.
2 Aortic dissection: Aneurysmatic dilation of the aorta with dissection flap type III, noticing true and false light.
In all the cases, it was shown a considerable anatomic resolution, with significant iconography.
Conclusions: M.R.I. is a non-invasive method of high anatomic resolution, with a wide range of possibilities in multiplanar resolution, allowing in the precise case of cardiac pathology the access to areas of the heart and mediastinum not easily visualized with other methods.

Top

poster2.jpg (120568 bytes)

cuadro1.gif (4980 bytes)

cuadro2.gif (5261 bytes)

cuadro3.gif (4395 bytes)

cuadro4.gif (4212 bytes)

 

Questions, contributions and commentaries to the Authors: send an e-mail message (up to 15 lines, without attachments) to image-pcvc@pcvc.sminter.com.ar , written either in English, Spanish, or Portuguese.

Preguntas a los Autores, comentarios y aportes: envíe un e-mail escrito en Español, Portugués o Inglés (de hasta 15 líneas, sin archivos agregados) a image-pcvc@pcvc.sminter.com.ar

Tope


© CETIFAC
Bioengineering
UNER

Update
Dic/08/1999


Colabora para la realización de este Congreso:

agilent.gif (2552 bytes)